关闭
 
读者在线:用户名 密码
首页 期刊简介 投稿须知 期刊目录 专家风采 编委会 特邀顾问 联系我们 移动出版
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5



刊物信息

期刊名称:药物分析杂志
主管单位:中国科学技术协会
主办单位:中国药学会
承办:中国食品药品检定研究院
主编:金少鸿
地址:北京天坛西里2号
邮政编码:100050
电话:010-67012819,67058427
电子邮箱:ywfx@nicpbp.org.cn
国际标准刊号:ISSN 0254-1793
国内统一刊号:CN 11-2224/R
邮发代号:2-237
 

访问统计
您是第  6 1 6 7 1 7 3 位浏览者
您当前的位置:首页 >> 正文

近红外光谱技术用于血必净注射液提取过程的在线检测研究

Near-infrared spectroscopy on-line and real-time monitoring of extraction process of Xuebijing Injection

分类号:
出版年·卷·期(页码):2012,32 (7):0-0
DOI: 10.16155/j.0254-1793.2017.01.01
-----摘要:-------------------------------------------------------------------------------------------

目的: 采用近红外透射光谱法,建立血必净注射液提取过程各质控指标的快速定量分析模型,并进行提取终点的快速判断,实现提取过程的在线检测。 方法: 以川芎、丹参和当归3种药材混合提取过程为例,采用偏最小二乘法回归(PLSR)分别建立阿魏酸浓度和含固量的定量校正模型,并将模型应用于提取过程的在线检测。使用移动块标准偏差(MBSD)算法实现对提取终点的快速判断。此外,采用模型更新方法,扩充原有模型,提高模型的稳定性和预测精度。 结果: 所建立的阿魏酸和含固量校正模型相关系数均达到0.986,采用所建模型进行在线分析,预测结果与实际测定值相关系数均大于0.967,预测相对偏差(RSEP)小于10%,相对分析误差(RPD)大于3。同时,MBSD算法的终点判断结果与实际相符。此外,将新的样品加入原校正模型进行模型更新后预测效果有所改善。 结论: 研究结果表明,利用近红外光谱技术可以实现提取过程中阿魏酸浓度和含固量的快速检测,并可快速判断提取终点。另外,模型更新方法有利于解决因药材质量、工况等发生变化导致的"模型失效"问题,从而扩展模型的使用范围。

-----英文摘要:---------------------------------------------------------------------------------------

Objective: To establish a rapid quantitative analysis model for quality control of Xuebijing Injection extraction with application of near-infrared (NIR) spectroscopy, and quickly determine the end point of extraction process, so as to realize on-line monitoring of the extraction process of Xuebijing Injection. Methods: Taking mixed extraction process of Ligusticum chuanxiong Hort., Salvia miltiorrhiza Bge.and Angelica sinensis (Oliv.) Diels for an example, partial least squares regression (PLSR) models were developed for the parameters of interest: total solid content and ferulic acid.The established PLS calibration models were used for on-line and real-time monitoring of the extraction process, and the moving block of standard deviation (MBSD) was used to identify the extraction end point.Furthermore, a model updating method was adopted to improve the stability and prediction accuracy of the calibration models. Results: The correlation coefficients of total solid content and ferulic acid models have reached 0.986.When the established models were applied to on-line monitoring, the correlation coefficients of prediction (r) and the residual predictive deviations (RPD) were above 0.967 and 3, respectively, and the relative standard errors of predictions (RSEP) were less than 10%.The result of MBSD was generally coincided with the variation of actual-measured ferulic acid concentration.In addition, the predictive accuracy was significantly improved after model updating with new samples. Conclusions: In this study, NIR spectroscopy was successfully applied to predicting total solid content and ferulic acid concentration in real-time and rapid determination of the extraction end point.Moreover, to solve the problem of calibration invalidation, the method of model updating was utilized to extend the use of established models and obtain better prediction results.

-----参考文献:---------------------------------------------------------------------------------------

欢迎阅读《药物分析杂志》!您是该文第 1597位读者!

药物分析杂志 © 2009
地址:北京天坛西里2号 邮政编码:100050; 电子邮件:ywfx@nicpbp.org.cn

本系统由北京博思汇文数字科技有限公司设计开发 技术服务电话:400-921-9838